What's happening with the home?
When was the home approved to be built (building licence or permit)?

Homes approved or started before 1 May 2015 don't need interconnected alarms for a sale or rental. Your local government holds the records.

How are the smoke alarms powered?

Mains alarms are fixed to a base wired into the ceiling. If you can't tell, the electrician can check.

Is there a ceiling space or wall cavity where a mains cable could run to each battery alarm?

Some concrete ceilings and flat roofs have none.

Is any alarm past its expiry date or, if it has none, installed 10 or more years ago?

The dates are printed on the back or side of each alarm.

Is there an alarm in each hallway outside the bedrooms, and one on every storey?
Do the alarms all sound together when you test one?

That means they're interconnected, by wire or wirelessly.

How many RCDs (safety switches) are on the switchboard?

RCDs have a button marked T or Test.

Do the RCDs cover every power point and lighting circuit?

The switchboard labels often show which circuits each RCD protects.

When you press each RCD's test button, does it switch off straight away?

to hand out, with the questions and the rules table.

Busselton Electrician: WA smoke alarm and RCD checklist · https://busseltonelectrician.com.au/tools/smoke-alarm-rcd-checker/ · Rules checked 5 October 2026

Your checklist

Answer the questions and press "Show my checklist". The result lists what WA law needs, who's responsible and what to ask a licensed electrician for, and you can print it.

This checker covers the common cases. Building and Energy WA has the final say.

WA smoke alarm and RCD rules for sales and rentals

The RCD rules are in Part IV of the Electricity Regulations 1947, which started on 9 August 2009 and took in short-term rental accommodation from 1 July 2024. The smoke alarm rules are in regulations 55 to 62 of the Building Regulations 2012.

What each situation needs

What each situation needs

SituationSmoke alarmsRCDs (safety switches)Who's responsible
SellingCompliant when ownership transfersProperly installed before the title is transferredThe seller. If it isn't done, the buyer must do it (RCDs within 2 months, smoke alarms within 12) and can recover the cost
Renting out (residential tenancy)Compliant before the tenant is entitled to move in, then maintained for the tenancyProperly installed before entering into a new tenancy agreementThe owner (landlord). Tenants change easy-to-reach 9-volt batteries and should test RCDs every three months
Holiday home or short-stay letCompliant before guests are entitled to stay, then maintainedProperly installed before the home is made available as short-term rental accommodationThe owner

From the Electricity Regulations 1947 Part IV, the Building Regulations 2012 regs 55–62, Building and Energy and Consumer Protection WA, checked 5 October 2026.

What counts as compliant smoke alarms
  • Installed to the Building Code that applied when they were put in
  • Not past the expiry date or, if there's none, installed less than 10 years ago
  • In working order
  • Permanently connected to mains power, unless there's no hidden space for the wiring and no suitable other spot, when a non-removable 10-year battery alarm is allowed
  • Interconnected where the Building Code needs it

Building and Energy notes that alarms powered through a home security system may not comply, because some security systems can be unplugged at the power point.

What counts as properly installed RCDs
  • At least two RCDs where the home has more than one circuit, and more where needed
  • Every circuit supplying power points and lights is protected
  • No RCD protects more than three circuits, and the lighting is split between them
  • Rated at 30 mA and fitted at the switchboard where the circuits start

Test each RCD every three months, or more often if the manufacturer's instructions say so. See Building and Energy's RCD safety switches page. For installation and testing, see smoke alarms and RCD testing in Busselton.

Common questions

Who can install smoke alarms and RCDs?

Only a licensed electrical contractor can connect or disconnect mains-powered smoke alarms or install RCDs. Owners and tenants can press the test buttons, and a tenant changes a 9-volt battery where the alarm is easy to reach.

What are the penalties?

The Electricity Regulations set fines of up to $15,000 for an individual for missing RCDs, with a $1,000 infringement notice. The Building Regulations set fines of up to $5,000 for missing smoke alarms, also with a $1,000 infringement notice.

Where these rules come from

The rules on this page come from these published pages, checked on 5 October 2026.